Precast Concrete Grease Interceptors
A simple, efficient solution to a growing
problem.
The many thousands of restaurants
in the United States serve nearly 70 billion meals
a year to their patrons. That’s a mountain of
food, whose preparation releases an ocean of wastewater
into the environment. The need for effective pretreatment
of that wastewater is crucial. Ineffective grease
removal from these waste streams results in the discharge
of large quantities of grease into public sanitary
sewer systems. Solidified grease can develop into
stoppages in the piping networks downstream and create
costly and time-consuming problems at municipal wastewater
treatment plants. Grease blockages have been known
to cause considerable unnecessary health hazards when
raw sewage backs up into residences or commercial
establishments. By trapping fats, oils and greases
(FOG) and solids normally found in food service establishments,
a grease interceptor is the last line of defense against
potential problems downstream.
More and more sanitarians and other
authorities are realizing that precast concrete grease
interceptors are the best solution for FOG removal.
Besides precast concrete grease
interceptors, alternative grease separation devices
such as small under-the-sink metal grease traps (sometimes
referred to as hydromechanical grease interceptors)
have been used at many food service establishments.
These small grease traps are often woefully inadequate
for commercial establishments. Whatever the system
in place, in order to allow for adequate separation
of the FOG from the waste stream, all grease separation
devices must be designed with the following criteria
in mind:
Retention
time
Greases and oils have a lower specific gravity than
water, so when a grease-laden mixture is left undisturbed,
they will float to the surface. As such, there must
be sufficient time for this process to occur. Smaller
devices should be carefully evaluated for retention
time. Metcalf & Eddy, an internationally acclaimed
company that delivers a full range of environmental
services, recommends a minimum retention time of 30
minutes to adequately separate a grease-laden mixture.
Flow
The grease separation device must be sized and configured
to allow for sufficient retention time, taking into
account the flow rate of the influent. Furthermore,
it must be configured to minimize turbulence and allow
the suspended FOG to separate. This is especially
important in high-flow situations, such as when draining
a large sink.
Storage capacity
The device must be large enough to allow for sufficient
storage of accumulated FOG between cleaning operations
without affecting the flow characteristics through
the unit.
Cleaning
frequency
The grease separation device must be sized according
to realistic cleaning frequencies. Under-the-sink
grease traps must be cleaned out routinely, even daily.
There is generally no assurance that restaurant personnel
will maintain the unit properly, so routine cleaning
performed by a third party will more likely result
in proper maintenance and supporting documentation.
In addition to all of the previously
mentioned design considerations, consider that soaps
and other emulsifying agents have a significant impact
on the amount of time required for the FOG to adequately
separate. Here is a quick and easy demonstration that
shows how soap drastically increases the time it takes
for FOG to separate effectively:
Given that all restaurants use soap,
it should be apparent that soaps’ effects on
separation time should be considered in the design
for grease separation devices. There are many variables
that affect the separation rate of emulsified FOG.
As such, consider that the separation time will be
increased by soap in order to ensure an appropriate
minimum retention time.
Outdoor precast concrete grease
interceptors can definitely accommodate all these
design requirements. Retention times in excess of
30 minutes are easily achievable. Baffles and large
liquid volumes help reduce turbulence and provide
for a high storage capacity. Outdoor interceptors
can provide maintenance accountability because of
their reliance on third-party maintenance contractors.
Another consideration is that outdoor interceptors
provide a level of health and safety that indoor traps
cannot provide. By physically removing the collection,
maintenance and disposal of grease outside the kitchen
area, outdoor interceptors eliminate the health concerns
otherwise created by providing these functions in
the same workspace as food preparation.